Shenzhen Optico Communication Co., Ltd. is one of the most credible manufacturers and suppliers of sc to lc fan-out patch cable 12 f in China. Please feel free to wholesale high quality customized products at competitive price form our factory. If you have any enquiry about free sample, please feel free to email us.
Product Profile
SC to LC Fan-Out Patch Cable 12F is a type of fiber optic cable that features features an SC connector on one end and an LC connector on the other end, with a fan-out design that splits the LC connector into 12 fibers. The fan-out design allows for the connection of multiple LC devices to a single SC device, making it a convenient solution for applications that require the connection of multiple fibers in a small space.
OPTICO's SC to LC Fan-Out Patch Cable 12F is available in various lengths and can be customized to meet your specific requirements. So whether you're looking to connect different types of equipment or simply need a flexible, high-performance fiber optic cable, we have got you covered.
Product Features
Low Insertion Loss
High Return Loss
Flame Retardant and UV Resistant: The SC to LC Fan-Out Patch Cable's jacket is made of LSZH (Low Smoke Zero Halogen) material and is safe for use in confined spaces.
A Wide Temperature Range
12-fiber Construction with a Fan-out Design: This design allows for greater flexibility in cable routing, especially when connecting equipment that is not located in close proximity to each other. The fan-out design also helps to reduce the overall size of the cable bundle, making it easier to manage and organize.
Compliant with RoHS, TIA/EIA, and ISO

High Quality Fiber

Bend-insensitive design

CCTC Ceramic ferrule(Low IL)

LSZH compliant
Our Brand Confidence Comes from a Strong Production Team
Applications

Optical fiber wiring

Data center

FTTH Network

Communication System
The strict test of our production line
IL/RL test
3D test
End face test

Temperature cycle
Rich warehousing, global distribution

Certificates
CE

CPR

ISO
RoHS
Full Ranges Of Reliability Tests From Third-party Lab

Coupling Test

Drop Test

Durability Test

High-Constant Temperature and Humidity Test

High-Low Temperature Test

Loss Test

Micro Cross Section Inspection Test

Resistant to Repeated Bending Test

Single Vertical Burning Test

Temperature Change Test

UV Test
Mission will be achieved in 7-15 days

Fiber patch cords are currently widely used indoors, such as buildings, work, office parks, campuses, and so on. So how to choose PVC, LSZH or OFNP outer sheath depends on the environment in which the optical fiber is selected.
The PVC outer covering has the characteristics of anti-oxidation and anti-degradation, and is usually used for the horizontal operation of the wiring center. Good mechanical properties and moderate price.
The outer cover of LSZH has a special flame-retardant coating, and has excellent fire safety performance of low smoke, low toxicity and low corrosion. Usually used for flat ground connection between buildings.
OFNP is the highest grade material, usually installed in the air return pressurization system used in ventilation ducts or air handling equipment, and meets NFPA fire safety regulations.
Hot Tags: sc to lc fan-out patch cable 12 f, China, manufacturers, suppliers, factory, wholesale, customized, 6 strand om3 armored fiber, multimode patch cable single mode, sc upc to sc apc patch cord, patch cord sc apc lc upc, sc patch cable, 6 strand armored fiber optic cable
| Specifications | SC,LC,FC,E2000 | ST,MU | MTRJ | ||||
| SM | MM | SM | MM | SM | MM | ||
| UPC | APC | UPC | UPC | UPC | UPC | UPC | |
| Work Wavelength (nm) | 1310,1490,1550 | 850,1300 | 1310, 1490,1550 | 850,1300 | 1310,1490,1550 | 850,1300 | |
| Insertion Loss(dB) | ≤0.25 | ≤0.20 | ≤0.25 | ≤0.25 | ≤0.25 | ≤0.25 | ≤0.25 |
| Return Loss(dB) | ≥55 | ≥65 | ≥35 | ≥50 | ≥35 | ≥50 | ≥35 |
| Repeatability(dB) | ≤0.10 | ||||||
| interchangeability(dB) | ≤0.20 | ||||||
| Plug Testing(time) | ≥1000 | ||||||
| Tensile Strength(N) | 0.9mm(9N);2.0mm(70N);3.0mm(75N) | ||||||
| Durability(dB) | ≤0.20 | ||||||
| Operation Temperature(°C) | -40~+75 | ||||||
| Storage Termperature(°C) | -40~+85 | ||||||